Home arrow Selecting a TCO arrow TCO Catalogs arrow ELCUT TCOs arrow Axial Leads arrow Standard arrow 12 Series
Wednesday, 08 February 2012
TCO Catalog >> NEC/Schott SEFUSE organic pellet and Uchihashi ELCUT eutectic thermal cutoffs
  Print this page


* These items are available in limited quantities and cannot be reordered.
 
Ratings
Buy Part
Number
Rated
Functioning
Temperature
Tf (°C)
Cut-off
Temperature
(°C)
(Functioning Temperature)
Th
Tc
(°C)
Tm
(°C)
Electrical Rating Approvals
Ampere
(A)
Voltage
(V)
UL
CSA
VDE
CCC
PSE
12N*
98
94 ± 3
72
72
67
67
200
AC 1.5
AC 2
AC 5
DC 5
AC 250
AC 125
AC 50
DC 50
121
102
98 ± 2
76
200
AC 2
AC 250
122
115
112 ± 3
89
200
AC 2
AC 250
123
130
126 ± 2
102
90
200
AC 2
DC 5
AC 250
DC 50
124
133
130 ± 2
108
200
AC 2
AC 250
128
139
135 ± 3
113
95
200
AC 2
DC 5.5
AC 250
DC 50
125
150
145 ± 2
123
200
AC 2
AC 250
127
187
184 ± 3
163
200
AC 2
AC 250
 
* These items are available in limited quantities and cannot be reordered.

Cut-off temperature is measured with silicone oil bath of which temperature is increased at the rate of 1° per minute. Detecting current is 0.1A or less.
Th and Tc are for C-UL(CSA) and CCC respectively.
 
Dimensions
Features
Dimensions (mm)
Lead length A B C D E
Regular
 
Technical Terms
  • Rated Functioning Temperature (Tf)
    The acceptable tolerance is +0,-10°C

  • Holding Temperature (C-UL&CSA:Th, CCC:Tc)
    The maximum temperature at which the thermal cutoffs may be maintained.

  • Maximum Temperature Limit (Tm)
    The maximum temperature at which an opened thermal cutoff does not reclose.

Notice: Please read Standard Specification and Instruction Manual for details of use.