Home arrow TCO Catalogs arrow ELCUT TCOs arrow Axial Leads arrow Standard arrow 44 Series
Tuesday, 06 January 2009
TCO Catalog >> NEC/Schott SEFUSE organic pellet and Uchihashi ELCUT eutectic thermal cutoffs
  Print this page
RoHS Compliant
Ratings
Part
Number
Rated
Functioning
Temperature
Tf (°C)
Cut-off
Temperature
(°C)
Th
Tc
(°C)
Tm
(°C)
Electrical Rating Approvals
Ampere
(A)
Voltage
(V)
UL
CSA
VDE
CCC
PSE
441
102
98 ± 2
76
76
74
74
200
AC 0.5
AC 1
AC 2.5
DC 2.5
AC 250
AC 125
AC 50
DC 50
442
115
112 ± 3
99
99
84
84
200
1
1.5
3.5
3.5
AC 250
AC 125
AC 50
DC 50
443
130
126 ± 2
111
111
102
102
200
AC 1
AC 1.5
AC 3.5
DC 3.5
AC 250
AC 125
AC 50
DC 50
444
133
130 ± 2
114
114
107
107
200
AC 1
AC 1.5
AC 3
DC 3
AC 250
AC 125
AC 50
DC 50
448
139
135 ± 3
119
119
106
106
200
AC 1
AC 1.5
AC 4
DC 4
AC 250
AC 125
AC 50
DC 50
445
150
145 ± 2
123
123
119
119
200
AC 0.5
AC 1
AC 4
DC 4
AC 250
AC 125
AC 50
DC 50
447
187
184 ± 3
162
162
155
155
200
AC 1
AC 1.5
AC 4
DC 4
AC 250
AC 125
AC 50
DC 50
 
UL,C-UL:E50082, CSA: LR40743, VDE: 923000-1171-0004
Cut-off temperature is measured with silicone oil bath of which temperature is increased at the rate of 1° per minute. Detecting current is 0.1A or less.
Th and Tc are for C-UL(CSA) and CCC respectively.
 
Dimensions
Dimensions (mm)
Lead length A B C D E
Regular ± 0.5
39 ± 3
69 ± 3
1.65 ± 0.1 2 or below 0.53 ± 0.02
Long
 
Technical Terms
  • Rated Functioning Temperature (Tf)
    The acceptable tolerance is +0,-10°C

  • Holding Temperature (C-UL&CSA:Th, CCC:Tc)
    The maximum temperature at which the thermal cutoffs may be maintained.

  • Maximum Temperature Limit (Tm)
    The maximum temperature at which an opened thermal cutoff does not reclose.

Notice: Please read Standard Specification and Instruction Manual for details of use.