Home arrow About CCI arrow TCO Catalogs arrow ELCUT TCOs arrow Axial Leads arrow Standard arrow 22 Series
Tuesday, 07 February 2012
TCO Catalog >> NEC/Schott SEFUSE organic pellet and Uchihashi ELCUT eutectic thermal cutoffs
  Print this page


* These items are available in limited quantities and cannot be reordered.
RoHS Compliant
Ratings
Buy Part
Number
Rated
Functioning
Temperature
Tf (°C)
Cut-off
Temperature
(°C)
(Functioning Temperature)
Th
Tc
(°C)
Tm
(°C)
Electrical Rating Approvals
Ampere
(A)
Voltage
(VAC)
UL
CSA
VDE
CCC
PSE
221R
102
98 ± 3
83
79
200
4
5
250
125
222R
115
112 ± 3
92
83
200
5
7
AC 250
AC 125
223R
130
126 ± 3
102
200
5
7
250
125
225R
150
146 ± 3
123
200
5
7
250
125
 
UL,C-UL:E50082, CSA: LR40743, VDE: 923000-1171-0002
 
* These items are available in limited quantities and cannot be reordered.

Cut-off temperature is measured with silicone oil bath of which temperature is increased at the rate of 1° per minute. Detecting current is 0.1A or less.
Th and Tc are for C-UL(CSA) and CCC respectively.
 
Dimensions
Features
Dimensions (mm)
Lead length A B C D E
Regular 11.5 ± 0.5
37 ± 3
67 ± 3
3.3 ± 0.2 3.6 or below ± 0.05
 
Technical Terms
  • Rated Functioning Temperature (Tf)
    The acceptable tolerance is +0,-10°C

  • Holding Temperature (C-UL&CSA:Th, CCC:Tc)
    The maximum temperature at which the thermal cutoffs may be maintained.

  • Maximum Temperature Limit (Tm)
    The maximum temperature at which an opened thermal cutoff does not reclose.

Notice: Please read Standard Specification and Instruction Manual for details of use.